Pass4sure---help you pass any IT exam Free Testking Braindumps

pass4sure emc e20-817 2.95

Symmetrix Business Continuity Expert Exam for Storage Admins : e20-817 Exam

Product Description

Exam Number/Code: e20-817

Exam Name: Symmetrix Business Continuity Expert Exam for Storage Admins

“Symmetrix Business Continuity Expert Exam for Storage Admins”, also known as e20-817 exam, is a EMC certification. With the complete collection of questions and answers, Pass4sure has assembled to take you through 132 Q&As to your e20-817 Exam preparation. In the e20-817 exam resources, you will cover every field and category in EMC Certification helping to ready you for your successful EMC Certification.

Preparing for the e20-817 exam? Searching e20-817 Test Questions, e20-817 Practice Exam, e20-817 BrainDumps? Pass4sure e20-817 is written to coincide with the real test by the experienced IT experts and specialists. With the complete collection of Pass4sure Questions and Answers, Pass4sure e20-817 is high enough to help the candidates to pass this exam easily without any other study materials and no need to attend the expensive training class.

Why choose Pass4sure e20-817 braindumps

Quality and Value for the e20-817 Exam
100% Guarantee to Pass Your e20-817 Exam
Practice Test Questions accompanied by exhibits

Pass4sure e20-817 Exam Features

Downloadable, Pass4sure Interactive e20-817 Testing engines

Pass4sure EMC e20-817 Downloadable, Printable Exams (in PDF vce format)

Our Exam e20-817 Preparation Material Labs provides you everything you will need to take your e20-817 exams. The e20-817 study guide Exam details Tutorials are researched and produced by Professional Certification Experts who are constantly using industry experience to produce precise, and logical. You may get questions from different web sites or books, but logic is the key. Our Product will help you not only pass in the first try, but also save your valuable time.
4. A customer running SRDF/Star experienced a workload site failure. Production was switched from the
workload site A to the synchronous target site B. Some time later, site A came back online. Before switching
production back to site A, a symdev show command is executed to examine the R1 devices at site A.
What is the RDF configuration state that describes the relationship of the RDF devices between A and B?
A.Duplicate
B.Half
C.Normal
D.PartitionedAnswer: A

5. A customer has a 5 (five) node Microsoft cluster (MSCS) that spans across 2 (two) sites over a SRDF/A link.
Site A, the primary site, contains 3 (three) nodes. Site B, the remote site, contains 2 (two) nodes. If the customer is
using SRDF/CE with Majority Note Set (MNS), what happens to the nodes at Site A if communication is lost
between the 2 (two) sites?
A.Nodes at Site A and Site B will go offline until communication resumes to Site B. The nodes at both sites need
to be started manually, and the /ForceQuorum switch must be used.
B.Nodes at Site A will go offline until communication resumes to Site B. The nodes at Site A need to be started
manually and the /ForceQuorum switch must be used.
C.Nodes at Site A will go offline until the nodes at Site A are manually started and the /ForceQuorum switch is
used.
D.Nodes will remain online.Answer: D

6. A company has a five-node MSCS cluster running SRDF/CE with three nodes at the primary site and two nodes
at the secondary site. The sites are 10 km apart. Due to capacity requirement changes, additional storage is
needed.
What must be done to the cluster after the storage configuration changes?
A.No action is required with MSCS after storage provisioning. All storage configuration updates are propagated
automatically via the COM server to the cluster nodes.
B.SRDF/CE cluster requires use of the COM server that must be restarted after all configuration changes. Once a
change is made to a node configuration, it will send out a message to all other cluster node members after the
service restarts.
C.The clusters must be rebooted, and a complete rescan of the system bus is required. Any current patches should
be applied at this time.
D.Update the SRDF/CE database by issuing a Symmetrix SRDF/CE Discover through the console or manually
setting symcli_db_file to srdfcesymapi.db followed by the symcfg discover command.Answer: D

Free Pass4sure Practice Engine Demo Download Pass4sure offers free demos for each certification exam, including all IT vendors. You can check out the testing engine software, or pdf file question quality and usability of our practice exams before you decide to buy it. We are the only one site that offers demos for almost all IT certification exams.If you want to try p4s exam practice engine demo. www.pass4sure.org.cn/braindumps/download/p4s/iengine/ www.pass4sure.org.cn/free_testking/download/demo/pdf

7. Your client has 10 large Microsoft Exchange servers. Currently, the backups to tape are not completing in the
backup window. The database cannot be stopped, and the client has no capacity to increase the number of tape
drives available.
How will you help solve the clients problem and provide the shortest possible backup window?
A.Add local BCVs to the Exchange Server disk and use TF/EIM to perform parallel backups.
B.Replicate the data to a disaster recovery site and use TF/SIM to perform tape backups.
C.Use TF/EIM to perform parallel backups directly to tape.
D.Use the EMC EDM product to call the Microsoft Exchange Online Backup API to back up the data to tape.
Answer: A

8. Your customer requests an immediate point-in-time copy of their production Oracle database but cannot have
the application brought down.
Which Enginuity feature allows the creation of restartable copies without quiescing the database?
A.Double Checksum
B.Enginuity Consistency Assist
C.Multi-Session Consistency
D.Symmetrix Differential Data Facility
Answer: B

9. An application has a BC requirement of two independent full concurrent copies of production each night. One
copy is mounted up for backup and recovery (BURA); the other is mounted up on a target server for data
warehouse operations.
The current STD device configuration is a four-member mirrored meta. The current BCV device configuration is a
four-member unprotected meta. The Symmetrix has global hot sparing enabled.
Which local EMC replication product(s) will enable the same number of replications as well as an additional
SRDF device?
A.Symmetrix Optimizer
B.TimeFinder/Clone
C.TimeFinder/Snap
D.TimeFinder/SRDF
Answer: B

10. You are designing an SRDF service level plan for a customer. Their needs assessment shows the following:
Performance: Remote replication with potential impact, depending on distance and network latency for
synchronous leg
Availability: Zero data exposure in the event of a source failure; no data loss on a single point of failure
Functionality: Continuous real-time mirroring on synchronous leg, Unlimited distances with no additional host
impact for asynchronous leg, and the ability to synchronize between two remote sites
Economics: Requires sufficient bandwidth to support peak workload requirements
Which SRDF mode of operation should be chosen?
A.SRDF/A
B.SRDF/DM
C.SRDF/S
D.SRDF/Star
Answer: D

11. A company migrates their Windows 2003 Exchange servers. After this has been completed the systems
administrator notes that performance has degraded on one of the Exchange servers. Analysis indicated that the
system is performing two reads or writes for transactions 15% of the time.
What is the probable cause?
A.Block size is too small.
B.Read cache is turned off.
C.Sectors are misaligned.
D.Stripe size is too small.
Answer: C

12. A company had their SRDF links go down while the R1BCV was in the process of synchronizing with the
STDR2. A few minutes later the TimeFinder Integration Module for Exchange found inconsistencies in the
information store of the local STDR1 device. The SRDF link comes back up.
What must the storage administrator do next?
A.Restore the STD from the STDR2.
B.Establish the R1BCV with the STDR2.
C.Keep the data from becoming unusable at the remote location.
D.Split the BRBCV from the STDR2.
Answer: A

* pass4sure emc e20-817 Questions and Answers : 132 Q&As
* Updated: October 29th , 2008
* Price: $159.99 $119.99
Free down:Pass4sure EMC e20-817
Free down:Testking EMC e20-817
EMC e20-817 Torrent
EMC e20-817 Real Exams
EMC e20-817 Actual Tests

Bookmark and Share
download Free Testking
P4S Free Downloads

Type

Exam Braindumps New Questions & Answers

Latest Updated

Available link
Testking torrent All Pass4sure's Exam Pack

858

1 days ago Download Free Testing Engines

Testking Braindumps-Free Testking Help You Quick Pass Any it Certifications Exams

,Click links: http://www.testking.la/braindumps/free/down/crack/all/testking
Share and Enjoy:
  • Digg
  • Sphinn
  • del.icio.us
  • Facebook
  • Mixx
  • Google Bookmarks
  • e-mail
  • Technorati
  • De.lirio.us
  • IndianPad
  • YahooMyWeb

Random Posts

Google

Top Posts for Today

2 Comments »

  1. Comment by Sam

    Not able to download any of these

  2. Pingback by Testking emc e20-817 | Download Free Latest Testking Certification Exams Training vce PDF Materials Braindumps

    [...] Number: e20-817 Exam Exam Name: Symmetrix Business Continuity Expert Exam for Storage [...]

RSS feed for comments on this post. TrackBack URI

Leave a comment

If you want to leave a feedback to this post or to some other user´s comment, simply fill out the form below.

(required)

(required)


Free Exam Dumps
Visited 57 times, 3 so far today

Bad Behavior has blocked 2951 access attempts in the last 7 days.