pass4sure hp HP0-241 2.83
Supporting the Enterprise Virtual Array (EVA) Storage Family : HP0-241 Exam
Product Description
Exam Number/Code: HP0-241
Exam Name: Supporting the Enterprise Virtual Array (EVA) Storage Family
“Supporting the Enterprise Virtual Array (EVA) Storage Family”, also known as HP0-241 exam, is a HP certification. With the complete collection of questions and answers, Pass4sure has assembled to take you through 148 questions to your HP0-241 Exam preparation. In the HP0-241 exam resources, you will cover every field and category in HP Certification helping to ready you for your successful HP Certification.
Preparing for the HP0-241 exam? Searching HP0-241 Test Questions, HP0-241 Practice Exam, HP0-241 BrainDumps? Pass4sure HP0-241 is written to coincide with the real test by the experienced IT experts and specialists. With the complete collection of Pass4sure Questions and Answers, Pass4sure HP0-241 is high enough to help the candidates to pass this exam easily without any other study materials and no need to attend the expensive training class.
Why choose Pass4sure HP0-241 braindumps
Quality and Value for the HP0-241 Exam
100% Guarantee to Pass Your HP0-241 Exam
Practice Test Questions accompanied by exhibits
Pass4sure HP0-241 Exam Features
Downloadable, Pass4sure Interactive HP0-241 Testing engines
Pass4sure HP HP0-241 Downloadable, Printable Exams (in PDF vce format)
Our Exam HP0-241 Preparation Material Labs provides you everything you will need to take your HP0-241 exams. The HP0-241 study guide Exam details Tutorials are researched and produced by Professional Certification Experts who are constantly using industry experience to produce precise, and logical. You may get questions from different web sites or books, but logic is the key. Our Product will help you not only pass in the first try, but also save your valuable time.
Question: 11
You are installing a VA7110 with one Fibre Channel (FC) switch and 2 HP/UX servers. After
completing the installation and configuration, you change the Domain ID on the FC switch. What
will happen?
A. The VA shuts down.
B. The HP-UX hardware path changes.
C. The switch shuts down.
D. The server shuts down.
Answer: B
Question: 12
Installing a VA7110 with a total capacity of 60 disks is ____.
A. possible with 3 disk enclosures DS2405
B. possible with 4 disk enclosures DS2400
C. possible with 4 disk enclosures DS2405
D. not possible
Answer: D
Question: 13
What happens to the data in the write cache after it has been written to disk?
A. It is kept in cache but space is marked as vailable”.
B. It will be deleted from cache.
C. It remains in cache for at least the next 4 seconds.
D. It is kept in cache but space is marked as pot available”.
Answer: A
Question: 14
How does a VA online controller firmware upgrade impact hosts and data accessibility?
A. Hosts have to be offline to prevent data corruption.
B. Hosts and switches have to be offline.
C. Hosts and LUNs can be online, but I/O from the VA will pause for approximately 10-30
seconds.
D. Hosts and LUNs can be online, but disk rescan should be initiated after the upgrade.
Answer: C
Question: 15
Which performance metrics are available exclusively for the VA7410? Select TWO.
A. per controller
B. per LUN
C. per HOSTPORT
D. per device
E. per JBODPORT
Answer: C, E
Question: 16
The ARMPERF command can be used to export performance data in which formats?
A. CSV and HTML
B. CSV and TXT
C. HTML only
D. CSV, HTML, and XML
Answer: B
Question: 17
The capacity allocated by the Active Spare feature in a Redundancy Group (RG) is ______.
A. defined by the user
B. equal to the size of the largest disk in the RG
C. equal to the size of the largest LUN in the RG
D. equal to the average size of the disk in the RG
Answer: B
Question: 18
What is required when changing from AutoRAID to RAID 1+0 mode?
A. User data must be backed up and restored.
B. LUNs must be unmounted and mounted back to hosts.
C. Nothing. The process is online and transparent to hosts.
D. The armrecover command must be used to recover customer data.
Answer: A
Question: 19
Auto rebuild can negatively impact performance if ___.
A. it is disabled, since data has to be recalculated upon request
B. it is enabled and rebuild is set to high priority
C. there is only one controller, since it has to do all the rebuilding
D. there are two controllers, since the one rebuilding will fail over the rest of work to the active
one
Answer: B
* pass4sure hp HP0-241 Questions and Answers : 148 questions
* Updated: October 29th , 2008
* Price: $159.99 $99.99
Free down:Pass4sure HP HP0-241
Free down:Testking HP HP0-241
HP HP0-241 Torrent
HP HP0-241 Real Exams
HP HP0-241 Actual Tests
HP Certified Professional
Supporting the Enterprise Virtual Array (EVA)
Storage Family (HP0-241)
Exam Preparation Guide
Free PassGuide Practice Engine Demo Download
Pass4sure offers free demos for each certification exam, including all IT vendors. You can check out the testing engine software, or pdf file question quality and usability of our practice exams before you decide to buy it. We are the only one site that offers demos for almost all IT certification exams.If you want to try p4s exam practice engine demo.
http://demo.passguide.com/download
Purpose of the exam prep guide
The intent of this guide is to set expectations about the content and the
context of the exam and to help candidates prepare for it. In this guide, you
will find recommended HP training courses, reference and study material to
help you achieve a successful passing score.
Studies conducted by HP and Prometric show that a combination of course
attendance and self-study maximizes the likelihood of passing the exam on
the first attempt.
Audience
The Supporting the Enterprise Virtual Array Storage (EVA) Family exam is for
engineers who support, from a Services perspective, the Enterprise Virtual
Array product line.
Examples of job roles: HP ASE engineer HP Services field engineers, call center personnel, and other field
personnel who provide installation and/or operational support assistance HP Channel Partners supporting the EVA product line (e.g., engineers
who perform warranty, break-fix, and installation services)
General areas of content include: EVA physical layout; hardware and software attributes and features HSV controller, disk drive enclosures and Fibre Channel loop switch Rack, cabling, configuration, and initial setup Storage Management Appliance Storage system configuration using Command View EVA Storage system management Error reporting and diagnostics Storage System Scripting Utility Best practices and storage tools Troubleshooting
Certification requirements
The Supporting the Enterprise Virtual Array (EVA) Storage Family (HP0-241)
exam is an Accredited Systems Engineer (ASE) core elective exam. This
exam is for individuals who, in addition to configuration, design, start-up, and
implementation services, will also deliver warranty and break-fix services for
the EVA family of arrays. Individuals who provide EVA start-up and
implementation services only for the EVA arrays should consider the !°less
services-focused!± HP0-690 exam instead of HP0-241.
Prerequisites AIS StorageWorks certification Knowledge of/completion of prerequisite Web-based and Instructor Led
Training Courses specified in the Recommended Training and Study
References section of this exam preparation guide. Knowledge of OpenView and SANworks software products through
appropriate training courses
Exam details
At the beginning of the exam, you will be asked to answer several survey
questions. The survey has been designed to assist the exam development
team in accurately profiling test results and to improve future exams. Number of items: 58 Item types: Multiple choice Passing Score: 70% (raw score of 41) Time commitment: 90 minutes Reference Material: No on-line or hard copy reference material will be
allowed at the testing site.
Comments on the exam
During the exam, participants can make specific comments about the items
(i.e., accuracy, appropriateness to audience, etc). HP welcomes these
comments as part of our continuous improvement process.
Exam Registration
This exam is available at Prometric.
Exam content
The following information represents specific areas of content covered in the
exam. Use this outline to guide your study and to check your readiness for
the exam. The exam measures your understanding of these areas.
Supporting the Enterprise Virtual Array (EVA) Storage Family (HP0-241)
Exam Content
1.0 Product Overview EVA physical layout Small Form Factor Pluggable (SFP). EVA3000 configurations and requirements
2.0 HSV Controller Controller features, components, functions, differences, and FRUs Host port WWNs Cache battery features and operation VCS licenses and revisions Fibre Channel speed and connection types Mirror port connections between HSV controllers Hot-swapping controllers
3.0 Disk Drive Enclosures M5×14 disk drive enclosure features and functions Controller connections to disk drive enclosures EMU components and functions Disk enclosure blower assembly Assignment of enclosure addresses
4.0 Fibre Channel Loop Switch Loop switch features included with EVA models Loop switch functional characteristics
5.0 Rack, Cabling, Configuration and Initial Setup Cabling configuration rules, including expansion racks Supported FC-AL devices Characteristics of switched and non-switched EVA configurations Key components and processes for cabling drive enclosure
configurations Key components for cabling expansion options
EVA system temperature ranges
6.0 Storage Management Appliance Hardware and software components of the HP OpenView Storage
Management Appliance (SMA) CommandView EVA software features and rules Configuring the SMA Restore CD purpose and features
7.0 Concepts and Terminology Purpose, features, and functions of a disk group and default disk group Distributed RAID Virtual disk cache options Data protection Disk leveling Disk group configuration Primary features of virtual disks Replication methods used with EVA (snapshots and snapclones)
8.0 Storage System Configuration Using Command View EVA Command View EVA Host Wizard Command View EVA storage system passwords Command View EVA functions Use of Command View EVA to initiate and complete configuration
process steps Steps in the configuration process of a storage system and host Properties of disk groups, virtual disks, and hosts Creating disk groups, virtual disks, hosts, snapshots and snapclones
9.0 Storage System Management Management agent options that can be set in Command View EVA Information displayed on a storage system!?s rack, controller, and disk
drive properties pages Licensing HSV controllers
10.0 Error Reporting and Diagnostics Event logs and how they are viewed Tools and processes used to translate and read controller event logs Steps involved to set up notification events for SNMP traps Tools and processes used to set up EVA remote monitoring (ISEE) Diagnostics used for the HSV controller
11.0 Storage System Scripting Utility (SSSU) SSSU purpose, features and functions Selecting a storage system and displaying information about the
elements in the selected storage system Capturing configuration information of a specified storage system into
script
12.0 Best Practices and Storage Tools Key considerations for configuring disk groups Calculating disk counts needed for the given requirements of a disk
group
13.0 Troubleshooting Event and error data used in troubleshooting Use of the controller and disk enclosure drive status indicators, tools,
and references for troubleshooting SAN information used for troubleshooting Replaceable units (FRUs and CRUs)
Recommended training and study references
This section lists training courses and documents that can help you acquire a
majority of the knowledge and skills needed to pass the exam. You must also
gain the practical experience outlined in this guide
You are not required to take the courses listed in this section. However, HP
strongly recommends that you attend the classes, participate in class labs,
and thoroughly review all course material and documents before taking the
exam, even if you believe you have sufficient on-the-job experience.
| P4S Free Downloads |
|
Type |
Exam Braindumps | New Questions & Answers |
Latest Updated |
Available link |
![]() |
All Pass4sure's Exam Pack |
858 |
1 days ago | Download Free Testing Engines |
PassGuide Braindumps-Free Test king Help You Quick Pass Any it Certifications Exams
Click links: www.testking.la/braindumps/free/down/crack/all/testkingPass Guide Training Materials Dumps
Top Posts for Today
- Huge Collection Of Pass4sure Actualtests Transcenders Sun, Oracle, HP, Citrix, Novell, Nortel etc other may request (2 views)
- pass4sure microsoft mcpd 70-547(VB) v2.93 (2 views)
- pass4sue hyperion 4h0-002 2.77 (2 views)
- Pass4sure 644-334 (2 views)
- passGuide promotional code (2 views)
- Pass4sure 000-M36 (2 views)
- All Cisco Pass4sure Actualtests Transcender Updated 5 May 2007 - Loaded Transcenders (2 views)
- free p4s sun exam (2 views)
- Pass4sure Microsoft Mcse Exams (2 views)
- pass4sure sas A00-211 2.93 (2 views)










Pingback by Testking HP HP0-241 | Free Download Latest pass4sure testking actualtest Hp Certification Exams Dumps
[...] HP Exam Code: HP0-241 Exam Name: Supporting the Enterprise Virtual Array (EVA) Storage [...]
Pingback by Testking HP HP0-241 | Download Free Latest Testking Certification Exams Training vce PDF Materials Braindumps
[...] Number: HP0-241 Exam Exam Name: Supporting the Enterprise Virtual Array (EVA) Storage [...]